Steps for Using MyLink Tool to Store Single-Axis Parameters
Launch the MyLink tool to enter the main operation interface
Check the box for the axis you want to work with and proceed to axis parameter settings
– For MIO logic settings, configure parameters such as ALM, +/-EL, INP, SD, and more
-Configure homing settings, including
-Mode selection
-ORG/EZ/ERC settings
-Configure Pulse In/Out settings, including
-Selection of the Pulse output interface
-Selection of the encoder input source and interface
-Decide whether numerical values should be in the negative direction
*Please note that these settings should match the actual configuration of the axis
3.After completing the parameter configuration, click on the “File” option in the toolbar and select “Backup Config to…
3.Select the pre-saved backup location
PC
EEPROM
5.After selecting “PC,”→ please click on the desired axis→ A new window will appear when you click “Browse.” →Enter the desired file name in the next window and click “Save” to complete the process
6.Select “EEPROM,”→ then check the desired axis for backup→ Click “Save.” After completion, a success message will appear, indicating that the backup has been stored in the module’s EEPROM