EtherCAT I/O Solutions-Taiwan Pulse Motion

How to Implement Line and ARC Functions with MyLink for PCE-M114GL

Step-by-Step Implementation Guide

  • Step One: Complete the MIO and PIO settings for the 4 axes
  • Step Two: Confirm that each individual axis can be controlled properly
  • Step Three: Click on the checkbox for the PCE-M114-GL card to enter the multi-axis operation function page
  • Step Four: Specify the operating axis and choose the operating function (Line / ARC)

Step One: Complete the MIO and PIO settings for the 4 axes

  • MIO:Motor Control Interface and Mechanism Points
    – Servo/Stepper Motor Interface I/O Point Settings
    – ALM
    – INP
    – ERC
    – Mechanism Points
    – EL
    – SD
  • Note: Pay attention to the following indicators during control
    – The indicators for EL+/EL- should not be lit simultaneously, indicating a logic error
    – ALM should not be lit
    – EMG should not be lit
如何實現MyLink操作PCE-M114GL的Line及ARC功能_完成4軸的MIO及 PIO設定-1
  • PIO:Motor Pulse Input/Output Interface and Encoder Feedback Interface
    – Servo/Stepper Motor Pulse Interface Requires Motor Configuration
    – Out/Dir: 4types
    – CW/CCW: 2types
    – A/B phase: 2types
    – Servo/Stepper Motor Encoder Feedback Interface Settings
    – Source Selection
    – Input Type Selection
    – A/B; 2xAV; 4AB; CW/CCW
如何實現MyLink操作PCE-M114GL的Line及ARC功能_完成4軸的MIO及 PIO設定-2

Step Two: Confirm that each individual axis can be controlled successfully

  • The forward and reverse operational directions are correct
    – Command/Position values are accurate
  • PEL/NEL match the forward and reverse directions
如何實現MyLink操作PCE-M114GL的Line及ARC功能_確認各單軸都可以正常控制

Step Three: Click on the checkbox for the PCE-M114-Gl card to enter the multi-axis operation functionality page

  1. Click on the checkbox for the PCE-M114-GL card
  2. Enter the multi-axis operation functionality page
  3. Basic operating parameters
    – MoveMode: Relative/ABS
    – StopMode: Sd/Emg top
    – VelProfile: T/S curve
    – MaxVel/StrVel
    – Tacc/Tdec
如何實現MyLink操作PCE-M114GL的Line及ARC功能_點擊PCE-M114-Gl卡勾選框,進入多軸操作功能頁面

Step Four: Specify the operating axis and select the operating function (Line/ARC)

  1. Specify the operating axis
  2. Choose interpolation method:
    – Line: Directly enter the Dist value
    – ARC: Set the following values
    – Cx/Cy: Center of the circle
    – Ex/Ey: End point of the operation Activate operations
  3. Activate operations
    – Reset: Reset Command/Encoder
    – Backward:Move backward
    – Stop:Stop operation
    – Forward:Move forward
如何實現MyLink操作PCE-M114GL的Line及ARC功能_指定運行軸及運行功能選擇(Line ARC)
Close
Select the fields to be shown. Others will be hidden. Drag and drop to rearrange the order.
  • Image
  • SKU
  • Rating
  • Price
  • Stock
  • Availability
  • Add to cart
  • Description
  • Content
  • 重量
  • 寸法
  • Additional information
Click outside to hide the comparison bar
比較
Close