-There are a total of 13 modes ranging from 0 to 12. For detailed information, please refer to Section 3.7.4 of the Motionnet Programming Manual
-For visual explanations of Home modes, consult pages 198 to 211 of the Motionnet Programming Manual
Related Procedure:
1.Complete all necessary configurations for the running axis
2.Select the relevant settings for the Home operation
-Configure the parameters required for the selected mode
3.Set the Home_Move parameters
4.Execute the Home operation
1.Complete axis configuration: -MIO Logic Settings -ALM/ERC/INP/SD, etc -Set according to servo/stepper driver specifications -PIO -Pulseoutput_mode -Configure the card’s output mode -OUT/DIR;CW/CCW;A/B phase -Pulse source -Encoder source -Internal -External -Command -PulseIN_mode -Set the card’s Encoder mode -1AB;2AB;4AB;CW/CCW -Pulse_Dir: Whether the values need a negative sign -Normal -Reverse
2.Configuration of Home -Select the Home mode (0~12, a total of 13 modes, refer to section 3.7.4 in the manual) -Depending on the chosen Home mode, specify the following: -ORGLogic -EZLogic -EZ Count, provide a value as needed based on the mode -ERC: No/Yes -ORG Offset: Provide a value as needed based on the mode
3.Configure Home_Move Parameters -After completing step 2 and configuring the Home mode and its settings -Select the execution mode → Home (as in the highlighted red box) -StrVel: Provide a value as needed (cannot be zero) -MaxVel:Provide a value as needed (cannot be zero) -Tacc:Provide a value as needed -Tdec:Provide a value as needed 4.執行: -SVON → Forward (or Backward); (as shown in the right figure)