MyLink Axis Module Screen Explanation - Module Setting Area
5.Operation
Primarily used to select the operating mode and parameters for operation
The parameters set in this area will not be saved in EEPROM or backup files, etc
Move_Mode
– Specifies the current operating mode for the designated axis – Relative : Performs relative mode movement – Absolute : Performs absolute mode movement – Continuous : Performs continuous movement at Max_Vel speed – Home_Move : Executes the Home function – Home_Search : Executes the Home Search function – Home_Escape : Executes the Home Escape function
StopMode
– The operating mode when the designated axis presses Stop on the operating screen – EmgStop / SdStop
VelProfile
– The operational speed curve mode when the designated axis presses Forward/Backward on the operating screen – Tcurve (see below) / Scurve(see below)
S-Curve
T-Curve
Dist
– The pulse quantity of axis movement when the designated axis presses Forward/Backward on the operating screen – Numeric setting range: 1~4294967296 (Pulse) – The pulse quantity for Relative mode movement – Position 1 for Absolute mode
Dist2: Only effective in Absolute mode
– Numeric setting range: 1~4294967296 (Pulse) – Position 2 for Absolute mode
StrVel: Specifies the initial speed (PPS) of axis movement when pressing Forward/Backward on the operation screen
– Numeric setting range: 1~6500000 (PPS) – Necessary requirements for this setting: – This value cannot be 0 – This value must be less than the set value of MaxVel
MaxVel: Specifies the maximum speed (PPS) of axis movement when pressing Forward/Backward on the operation screen
– Numeric setting range: 1~6500000 (PPS) – Necessary requirements for this setting: – This value cannot be 0 – This value must be greater than the set value of StrVel
Tacc:Specifies the acceleration time for axis movement when pressing Forward/Backward on the operation screen
– Unit: Seconds
Tdec:Specifies the deceleration time for axis movement when pressing Forward/Backward on the operation screen
– Unit: Seconds
Ratio: Adjusts the Command to Encoder ratio to 1 when the values are not 1:1
– After setting, it needs to be confirmed by pressing Ratio in the Auto Compare page to take effect
Backlash: Sets the compensation value generated due to backlash
– Takes effect when the axis undergoes reverse movement
5.Operation (Single Axis Operation Page)
Command : Displays the command value during axis movement
Position : Displays the feedback value during axis movement (based on PulseIn_Source)
Speed : Displays the speed value during axis movement
Mc Status : Displays the status of the axis
Operation : Selects the axis control page (default page)
– Repeat: Used to select the axis for repeated back-and-forth movements – SVON : Selects the axis to enter the energized state – Reset : Resets the Command/Encoder values to zero – Backward : Commands the axis to move in the negative direction based on Operation settings – Stop : Commands the moving axis to stop, according to the Operation mode (EmgStop/SDStop) – Forward : Commands the axis to move in the positive direction based on Operation settings – Repeat bar: Used to specify the pause time between axis back-and-forth commands when Repeat is activated
Auto Compare: Selects the axis control function page (Auto Compare / RALM / DO / ERC / Ratio)
– Auto Compare – Source Encoder : Displays the count value of the Compare source – TriggerOut : Press to force a single Trigger output – Clear : Clears the settings – Start : Press to command the axis into Auto Compare standby mode, based on the Compare settings – RALM : Reset Alarm – DO : digital output – ERC : Manual ERC output – Ratio : Configures the ratio of the axis’s Command to Encoder